On/Off

Attributes

Attribute ID Name Type Comments
0x0000 OnOff Boolean  
0x4001 OnTime Unsigned 16-bit integer Length of time (in 1/10ths second) that the “on” state shall be maintained 1438 before automatically transitioning to the “off” state when using the On with timed off command
0x4002 OffWaitTime Unsigned 16-bit integer Length of time (in 1/10ths second) that the “off” state shall be guarded 1442 to prevent an on command turning the light back to its “on” state

Commands

Off (0x00)

No arguments

On (0x01)

No arguments

Toggle (0x02)

No arguments

On With Timed Off (0x42)

Field Name Type Comments
Accept Only When On Unsigned 8-bit integer If true command shall be processed only when the OnOff attribute is equal to 0x01; otherwise command shall be processed unconditionally.
On Time Unsigned 16-bit integer  
Off Wait Time Unsigned 16-bit integer